Use of Exit QQMA0015 in Catalogs F4 help filtering.

$
0
0

Catalog-Codes F4 help filter facility through user-exit QQMA0015.

 

Catalog-coding functionality covers wide range of applications, hence configured in many

different ways to suit the  individual requirements.

 

In this document one such situation has been dealt, where user would like to filter the
F4 help of other catalogs as soon as he selects a code-group in object-part (Catalog B).

 

First let’s see what is this facility we are talking about.

 

Select a Code & Code Group  in the Catalog-codes tab of a notification.

(Say we have selected ‘DRIVE-SET’)

 

Capture.JPG

 

Upon selecting the ‘DRIVE-SET’ in the Object Part, the filter effect will be activated in the F4 help of all
other catalogs, by showing only the codes of the Code Group with same name (selected in catalog B).

 

Here on, this is how the F4 help is presented for other Catalogs (Catalog C is demonstrated here)

Capture1.JPG

Previously, without this filter, all the Code-Group folders were appearing from where you were required

to open the respective folder to select the desired Code.

 

Similar F4 help filter will be seen in all the other catalog tabs. (namely 5,2 and A).

 

Note: 

In spite of this arrangement, if one needs to override this, he can simply type the name of the other

desired Code Goup (say CG1 or CG2) in the Code Group cell and press Enter. The respective codes

will be appearing.

 

If the above feature looks interesting & useful, the following section demonstrates how to achieve this.

 

 

 

 

 

Let’s  suppose we have a coding data as under.

 

 

 

1.JPG

 

QS41:

  - Create Code Groups with same names across the 5 catalogs (Here these are CG1, CG2, CG3)

  - In Object part (B) maintain single code for each group ie., the part itself as shown below (QS41).

a.JPG

-  Complete other Coding (QS41) as per the above Excel-sheet data.

 

OQN6:

- Create a Profile as shown below.

 

prof.JPG

 

And assign this Profile (PUMPASSLY) to the respective Equipments.

 

 

The F4 Filter:

 

Write the following Code in the include ZXQQMU21 of user-exit QQMA0015.

-------------------------------------------------------------------------------------------------------

code.JPG

-------------------------------------------------------------------------------------------------------

 

Now the desired F4 help filter will be available.